<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>Analytical and Bioanalytical Electrochemistry is an international scientific journal published online by the Center of Excellence in Electrochemistry at the University of Tehran, Tehran, Iran. The journal was published quarterly from 2009 to 2011, bimonthly from 2011 to 2018, and has been published in at least eight issues per year since 2018.</PublisherName>
				<JournalTitle>Analytical and Bioanalytical Electrochemistry</JournalTitle>
				<Issn>-</Issn>
				<Volume>15</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2023</Year>
					<Month>01</Month>
					<Day>31</Day>
				</PubDate>
			</Journal>
<ArticleTitle>The Inhibiting Effect of Aqueous Extracts of Artemisia Absinthium L. (Wormwood) on the Corrosion of Mild Steel in HCl 1 M</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>17</FirstPage>
			<LastPage>35</LastPage>
			<ELocationID EIdType="pii">701392</ELocationID>
			
<ELocationID EIdType="doi">10.22034/abec.2023.701392</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>A</FirstName>
					<LastName>Hbika</LastName>
<Affiliation>Laboratory of Applied and Environmental Chemistry (LCAE), Team Applied Analytical Chemistry of Materials and Environment, Mohammed First University, Faculty of Science, Department of Chemistry, 60000 Oujda, Morocco</Affiliation>

</Author>
<Author>
					<FirstName>A</FirstName>
					<LastName>Bouyanzer</LastName>
<Affiliation>Laboratory of Applied and Environmental Chemistry (LCAE), Team Applied Analytical Chemistry of Materials and Environment, Mohammed First University, Faculty of Science, Department of Chemistry, 60000 Oujda, Morocco</Affiliation>

</Author>
<Author>
					<FirstName>M</FirstName>
					<LastName>Jalal</LastName>
<Affiliation>Laboratory of Applied and Environmental Chemistry (LCAE), Team Applied Analytical Chemistry of Materials and Environment, Mohammed First University, Faculty of Science, Department of Chemistry, 60000 Oujda, Morocco</Affiliation>

</Author>
<Author>
					<FirstName>N</FirstName>
					<LastName>Setti</LastName>
<Affiliation>Laboratory of Applied and Environmental Chemistry (LCAE), Electrochemical team, Mohammed First University, Faculty of Science, Department of Chemistry, 60000 Oujda, Morocco</Affiliation>

</Author>
<Author>
					<FirstName>E</FirstName>
					<LastName>Loukili</LastName>
<Affiliation>Laboratory of Applied and Environmental Chemistry (LCAE), Team Applied Analytical Chemistry of Materials and Environment, Mohammed First University, Faculty of Science, Department of Chemistry, 60000 Oujda, Morocco</Affiliation>

</Author>
<Author>
					<FirstName>A</FirstName>
					<LastName>Aouniti</LastName>
<Affiliation>Laboratory of Applied and Environmental Chemistry (LCAE), Team Applied Analytical Chemistry of Materials and Environment, Mohammed First University, Faculty of Science, Department of Chemistry, 60000 Oujda, Morocco</Affiliation>

</Author>
<Author>
					<FirstName>Y</FirstName>
					<LastName>Kerroum</LastName>
<Affiliation>Laboratory of Materials, Nanotechnology and Environment, Faculty of Sciences, Mohammed V University in Rabat, Av. Ibn Battouta, P.O. Box 1014 Agdal-Rabat, Morocco</Affiliation>

</Author>
<Author>
					<FirstName>I</FirstName>
					<LastName>Warad</LastName>
<Affiliation>Department of Chemistry, AN-Najah National University, P.O. Box 7, Nablus, Palestine</Affiliation>

</Author>
<Author>
					<FirstName>B</FirstName>
					<LastName>Hammouti</LastName>
<Affiliation>Laboratory of Applied and Environmental Chemistry (LCAE), Team Applied Analytical Chemistry of Materials and Environment, Mohammed First University, Faculty of Science, Department of Chemistry, 60000 Oujda, Morocco</Affiliation>

</Author>
<Author>
					<FirstName>Abdelkader M</FirstName>
					<LastName>Zarrouk</LastName>
<Affiliation>Laboratory of Materials, Nanotechnology and Environment, Faculty of Sciences, Mohammed V University in Rabat, Av. Ibn Battouta, P.O. Box 1014 Agdal-Rabat, Morocco</Affiliation>
<Identifier Source="ORCID">0000-0002-5495-2125</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2022</Year>
					<Month>12</Month>
					<Day>20</Day>
				</PubDate>
			</History>
		<Abstract>Using the decoction extraction method, we obtained twice crude aqueous extracts of Artemisia absinthium or (wormwood) that was made to start a comparative study, between the first extract which corresponds to the leaves of our plant (AQL) and the second which belongs to the stems (AQS). The inhibitory activity of the twice extracts of Artemisia absinthium was studied by weight loss, potentiodynamic polarization and electrochemistry impedance spectroscopy. The morphology of the mild steel surface was examined by SEM.The inhibitory efficiency increased with the increase of the concentration, we reach an efficiency of 85% for AQL and 82% for AQS at 303 K for a concentration of 0.2 g/ L. Two Artemisia absinthium extracts used to prevent corrosion in mild steel adhere to the Langmuir adsorption isotherm during adsorption. The majority compound is 3,4-dihydroxybenzoic acid in the case of extracts with percentages of 42.4% for AQL and 42.2% for AQS. The DFT results of the majority compounds allowed us to have an idea on the power of adsorption of these last ones on the surface of the metal, indeed there can be a combined effect of the various molecules constituting the extracts on the corrosion inhibition.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Artemisia absinthium</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Aqueous extracts</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Mild steel</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Corrosion inhibition</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">DFT</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.abechem.com/article_701392_03cefc6b2f1a055f8e404c87a6836557.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
