<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>Analytical and Bioanalytical Electrochemistry is an international scientific journal published online by the Center of Excellence in Electrochemistry at the University of Tehran, Tehran, Iran. The journal was published quarterly from 2009 to 2011, bimonthly from 2011 to 2018, and has been published in at least eight issues per year since 2018.</PublisherName>
				<JournalTitle>Analytical and Bioanalytical Electrochemistry</JournalTitle>
				<Issn>-</Issn>
				<Volume>16</Volume>
				<Issue>9</Issue>
				<PubDate PubStatus="epublish">
					<Year>2024</Year>
					<Month>09</Month>
					<Day>30</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Electrochemical Evaluation of Lemon Juice as a Chelating Agent for Calcium Oxalate Crystal Prevention in Crystalluria</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>809</FirstPage>
			<LastPage>816</LastPage>
			<ELocationID EIdType="pii">716094</ELocationID>
			
<ELocationID EIdType="doi">10.22034/abec.2024.716094</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Mohamed</FirstName>
					<LastName>Bouha</LastName>
<Affiliation>Laboratory of Engineering in Chemistry and Physics of Matter, Faculty of Science and Technology, Sultan Moulay Slimane University, Beni Mellal, Morocco</Affiliation>
<Identifier Source="ORCID">0000-0002-1996-4817</Identifier>

</Author>
<Author>
					<FirstName>Malika</FirstName>
					<LastName>Echajia</LastName>
<Affiliation>Laboratory of Engineering in Chemistry and Physics of Matter, Faculty of Science and Technology, Sultan Moulay Slimane University, Beni Mellal, Morocco</Affiliation>

</Author>
<Author>
					<FirstName>Mohamed</FirstName>
					<LastName>Berkani</LastName>
<Affiliation>Laboratory of Food Engineering and Technologies (LITA), Department of Chemistry and Environment, Faculty of Science and Technology, Sultan Moulay Slimane University, Beni Mellal, Morocco</Affiliation>

</Author>
<Author>
					<FirstName>Abderrahmane</FirstName>
					<LastName>Talfana</LastName>
<Affiliation>Laboratory of Engineering and Applied Technologies, School of Technology, Sultan Moulay Slimane University, Beni Mellal, Morocco</Affiliation>

</Author>
<Author>
					<FirstName>Issam</FirstName>
					<LastName>Forsal</LastName>
<Affiliation>Laboratory of Engineering and Applied Technologies, School of Technology, Sultan Moulay Slimane University, Beni Mellal, Morocco</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2024</Year>
					<Month>03</Month>
					<Day>11</Day>
				</PubDate>
			</History>
		    <Abstract>Crystalluria, characterized by the formation of calcium oxalate crystals, is a common urinary disorder. While increasing urinary volume is a traditional approach to manage this condition, novel therapeutic strategies are being explored. Lemon juice (LJ), rich in citric acid, is of particular interest due to its calcium ion chelating properties. This study evaluated the in vitro potential of LJ to inhibit calcium oxalate crystal formation. Using specialized electrodes (CPE-GC) and various electrochemical techniques (SWV, CV, LV, EIS), we characterized the interactions between LJ and calcium ions. Our findings, obtained from a simplified model using calcium carbonate, demonstrate the ability of LJ to effectively complex calcium ions, thereby reducing their availability for crystal formation. Although these results are promising, it&#039;s important to note that the experimental conditions do not fully replicate the complexity of physiological urine. In vivo studies are therefore necessary to confirm the efficacy of LJ in a clinical setting. In conclusion, lemon juice appears to be a promising approach for preventing calcium oxalate crystal formation. Its mechanism of action, based on calcium ion chelation, offers an alternative to conventional treatments. However, further research is required to evaluate its clinical efficacy and optimize its usage.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Crystalluria</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">calcium oxalate</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Lemon Juice</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">chelation</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Electrochemical methods</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.abechem.com/article_716094_548d2acdacc01c92ad5c7fd1e5189a1e.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Analytical and Bioanalytical Electrochemistry is an international scientific journal published online by the Center of Excellence in Electrochemistry at the University of Tehran, Tehran, Iran. The journal was published quarterly from 2009 to 2011, bimonthly from 2011 to 2018, and has been published in at least eight issues per year since 2018.</PublisherName>
				<JournalTitle>Analytical and Bioanalytical Electrochemistry</JournalTitle>
				<Issn>-</Issn>
				<Volume>16</Volume>
				<Issue>9</Issue>
				<PubDate PubStatus="epublish">
					<Year>2024</Year>
					<Month>09</Month>
					<Day>30</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Elimination of Copper from Wastewater Arising from Metal Plating Through Electrocoagulation</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>817</FirstPage>
			<LastPage>829</LastPage>
			<ELocationID EIdType="pii">716156</ELocationID>
			
<ELocationID EIdType="doi">10.22034/abec.2024.716156</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Ahmed</FirstName>
					<LastName>Salim</LastName>
<Affiliation>Laboratory of Physical Chemistry, Materials and Catalysis, Department of Chemistry, Ben M'Sick Faculty of Science, Hassan II University - Casablanca, Morocco</Affiliation>
<Identifier Source="ORCID">0009-0008-4756-0925</Identifier>

</Author>
<Author>
					<FirstName>A. El</FirstName>
					<LastName>Bouari</LastName>
<Affiliation>Laboratory of Physical Chemistry, Materials and Catalysis, Department of Chemistry, Ben M'Sick Faculty of Science, Hassan II University - Casablanca, Morocco</Affiliation>

</Author>
<Author>
					<FirstName>M.</FirstName>
					<LastName>Tahiri</LastName>
<Affiliation>Organic Synthesis, Extraction and Valorization Laboratory, Ain Chok Faculty of Science, Hassan II University - Casablanca, Morocco</Affiliation>

</Author>
<Author>
					<FirstName>O.</FirstName>
					<LastName>Tanane</LastName>
<Affiliation>Laboratory of Physical Chemistry, Materials and Catalysis, Department of Chemistry, Ben M'Sick Faculty of Science, Hassan II University - Casablanca, Morocco</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2024</Year>
					<Month>08</Month>
					<Day>31</Day>
				</PubDate>
			</History>
		    <Abstract>The pollution of aquatic ecosystems by heavy metals poses a significant and immediate environmental threat worldwide. Industrial operations often result in the direct discharge of effluents into rivers, lakes, and ponds, leading to the contamination of these water bodies. Subsequently, these pollutants can percolate into groundwater systems through a range of transport mechanisms. Although certain heavy metals play essential roles in the metabolic processes of organisms, their elevated concentrations in aquatic environments present substantial risks, disrupting ecological balance and potentially affecting human health. This study examines the process of copper (Cu) removal from wastewater using electrocoagulation techniques. The research found that the effectiveness of copper extraction increased with extended electrocoagulation times, higher concentrations of sodium chloride (NaCl), and elevated applied electric currents. The most efficient removal was achieved under optimal conditions, which is defined as an average pH level of about 4 and a current of 2 A , and a duration of electrolysis set at 60 minutes.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Wastewater</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">heavy metals</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">electrocoagulation</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">copper</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">electric currents</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.abechem.com/article_716156_bdd141e4dc9d74af421fe32d7a762c6e.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Analytical and Bioanalytical Electrochemistry is an international scientific journal published online by the Center of Excellence in Electrochemistry at the University of Tehran, Tehran, Iran. The journal was published quarterly from 2009 to 2011, bimonthly from 2011 to 2018, and has been published in at least eight issues per year since 2018.</PublisherName>
				<JournalTitle>Analytical and Bioanalytical Electrochemistry</JournalTitle>
				<Issn>-</Issn>
				<Volume>16</Volume>
				<Issue>9</Issue>
				<PubDate PubStatus="epublish">
					<Year>2024</Year>
					<Month>09</Month>
					<Day>30</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Unveiling The Multi Functionality of CeCuIn2O5 Nanoparticles: A Promising Approach For UV-Light Photocatalysis, Electrochemical Sensing and Antibacterial Applications</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>830</FirstPage>
			<LastPage>845</LastPage>
			<ELocationID EIdType="pii">716157</ELocationID>
			
<ELocationID EIdType="doi">10.22034/abec.2024.716157</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Shivaswamy</FirstName>
					<LastName>M B</LastName>
<Affiliation>Department of Chemistry, Sri Jayachamarajendra College of Engineering, JSS Science and Technology University, Mysuru, India-570 006, India</Affiliation>
<Identifier Source="ORCID">0009-0009-8081-5165</Identifier>

</Author>
<Author>
					<FirstName>Nagendra Prasad</FirstName>
					<LastName>H S</LastName>
<Affiliation>Department of Chemistry, Sri Jayachamarajendra College of Engineering, JSS Science and Technology University, Mysuru, India-570 006, India</Affiliation>
<Identifier Source="ORCID">0000-0002-8183-276X</Identifier>

</Author>
<Author>
					<FirstName>B. Manjappa</FirstName>
					<LastName>Kiran</LastName>
<Affiliation>Department of Chemistry, Tunghai University, No. 1727, Sec. 4, Taiwan Boulevard, Xitun District, Taichung City 40704, Taiwan, Republic of China</Affiliation>

</Author>
<Author>
					<FirstName>Madhushree</FirstName>
					<LastName>S</LastName>
<Affiliation>Department of Chemistry, Sri Jayachamarajendra College of Engineering, JSS Science and Technology University, Mysuru, India-570 006, India</Affiliation>

</Author>
<Author>
					<FirstName>Hemanth</FirstName>
					<LastName>B S</LastName>
<Affiliation>Department of Chemistry, Sri Jayachamarajendra College of Engineering, JSS Science and Technology University, Mysuru, India-570 006, India</Affiliation>

</Author>
<Author>
					<FirstName>Madhukar</FirstName>
					<LastName>B S</LastName>
<Affiliation>Department of Chemistry, Sri Jayachamarajendra College of Engineering, JSS Science and Technology University, Mysuru, India-570 006, India</Affiliation>

</Author>
<Author>
					<FirstName>Kavya</FirstName>
					<LastName>R</LastName>
<Affiliation>Department of Chemistry, Sri Jayachamarajendra College of Engineering, JSS Science and Technology University, Mysuru, India-570 006, India</Affiliation>

</Author>
<Author>
					<FirstName>Sangamesha</FirstName>
					<LastName>M A</LastName>
<Affiliation>Department of Chemistry, The National Institute of Engineering, Mysuru, India-570 00, India</Affiliation>

</Author>
<Author>
					<FirstName>Anand</FirstName>
					<LastName>A. P</LastName>
<Affiliation>Ganesh Consultancy and Analytical Servies, Hebbal Industrial Area, Mysuru, India-570016, India</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2024</Year>
					<Month>03</Month>
					<Day>30</Day>
				</PubDate>
			</History>
		    <Abstract>CeCuIn2O5 trimetallic oxide nanoparticles (CCI NPs) were synthesised in the current work and examined for antibacterial activity against Methicillin Resistant Staphylococcus Aureus (MRSA), photocatalytic degradation of malachite green (MG) and electrochemical sensing of sodium nitrite. The physicochemical characteristics of the CCI NPs were analyzed using XRD, SEM, EDX, UV-vis and DLS method which depicts the morphology, crystalline nature and particle size synthesised CCI NPs. With a linear range of 0.8-4.8mM, the glassy carbon electrode (GCE) modified CCI NPs demonstrated an outstanding electrochemical response for sodium nitrite (NaNO2). In addition, the synthesized CCI NPs showed high photocatalytic activities for the degradation of MG dye in water. It indicates the CCI NPs material produces hydroxyl (⋅OH) and superoxide (O2−) radicals for MG degradation when exposed to UV light, also showed an efficiency of 89.6% towards the degradation of Malachite Green. Carried out the dose-dependent method to the standard antibiotic streptomycin at 10 g/disc (5, 7, 15, 20, 25 &amp; 30) with a zone of inhibition (ZOI) of 25.27- 45.27±0.09 in mm CCI NPs showed excellent antibacterial activity against MRSA in a dose-dependent method. As a consequence, it was found that CCI NPs are an effective multifunctional material that can be scaled up for the quantification of NaNO2, photocatalytic dye degradation of malachite green, and antibacterial activity against MRSA.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Trimetallic nanoparticles</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Sodium nitrate</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Malachite green</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Electrochemical sensor</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Methicillin-Resistant Staphylococcus aureus</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.abechem.com/article_716157_0891c767eb8fea78290d3bd823f7aa6e.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Analytical and Bioanalytical Electrochemistry is an international scientific journal published online by the Center of Excellence in Electrochemistry at the University of Tehran, Tehran, Iran. The journal was published quarterly from 2009 to 2011, bimonthly from 2011 to 2018, and has been published in at least eight issues per year since 2018.</PublisherName>
				<JournalTitle>Analytical and Bioanalytical Electrochemistry</JournalTitle>
				<Issn>-</Issn>
				<Volume>16</Volume>
				<Issue>9</Issue>
				<PubDate PubStatus="epublish">
					<Year>2024</Year>
					<Month>09</Month>
					<Day>30</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Improving the Electrochemical Detection of Profenofos Insecticides based on TiO2@NiO-CuO Nanocomposite Doped Graphene Paste Electrode</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>846</FirstPage>
			<LastPage>861</LastPage>
			<ELocationID EIdType="pii">716161</ELocationID>
			
<ELocationID EIdType="doi">10.22034/abec.2024.716161</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Muhammad</FirstName>
					<LastName>Nurdin</LastName>
<Affiliation>Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Halu Oleo, Jl. H.E.A. Mokodompit Kampus Baru Anduonohu, Kendari 93232 – Southeast Sulawesi, Indonesia</Affiliation>
<Identifier Source="ORCID">0000-0002-6727-9283</Identifier>

</Author>
<Author>
					<FirstName>Maulidiyah</FirstName>
					<LastName>Maulidiyah</LastName>
<Affiliation>Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Halu Oleo, Jl. H.E.A. Mokodompit Kampus Baru Anduonohu, Kendari 93232 – Southeast Sulawesi, Indonesia</Affiliation>
<Identifier Source="ORCID">0000-0001-5643-9854</Identifier>

</Author>
<Author>
					<FirstName>Muhammad Zakir</FirstName>
					<LastName>Muzakkar</LastName>
<Affiliation>Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Halu Oleo, Jl. H.E.A. Mokodompit Kampus Baru Anduonohu, Kendari 93232 – Southeast Sulawesi, Indonesia</Affiliation>
<Identifier Source="ORCID">0000-0002-9749-0637</Identifier>

</Author>
<Author>
					<FirstName>Irwan</FirstName>
					<LastName>Irwan</LastName>
<Affiliation>Department of Pharmacy, Faculty of Sciences and Technology, Institut Teknologi dan Kesehatan Avicenna, Kendari 93117, Southeast Sulawesi, Indonesia</Affiliation>
<Identifier Source="ORCID">0000-0002-2249-465X</Identifier>

</Author>
<Author>
					<FirstName>Zul</FirstName>
					<LastName>Arham</LastName>
<Affiliation>Department of Mathematics and Natural Sciences, Institute Agama Islam Negeri (IAIN), Kendari 93563–Southeast Sulawesi, Indonesia</Affiliation>
<Identifier Source="ORCID">0000-0001-6644-8674</Identifier>

</Author>
<Author>
					<FirstName>Ahmad</FirstName>
					<LastName>Zulfan</LastName>
<Affiliation>Nickel Research Institute, Universitas Muhammadiyah Kendari, Jl. K.H. Ahmad Dahlan, Kendari, Southeast Sulawesi 93117, Indonesia</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2024</Year>
					<Month>04</Month>
					<Day>23</Day>
				</PubDate>
			</History>
		    <Abstract>A rapid and facile method for detecting profenofos is crucial for environmental surveillance and ensuring product quality. Electrochemical sensing, as appears presents significant potential as a nascent technology for profenofos detection in recent years. Herein, NiO-CuO bimetallic modified graphene paste electrode/TiO2 was developed for the detection of profenofos over cyclic voltammetry technique. The TiO2@NiO-CuO were synthesized through the sol-gel method and characterized by various analyses such as SEM, XRD, and FTIR and electrochemical techniques. The superior electrochemical properties of the suggested GPE/TiO2@NiO-CuO were demonstrated by cyclic voltammetry investigations performed in Fe(CN)64−/3− solution. The electrode performance of GPE/TiO2 doped with NiO-CuO towards K3FeCN6 solution is notably enhanced compared to GPE/TiO2 undoped. Doping notably increased the conductivity of the GPE/TiO2, leading to a performance enhancement in the electrocatalytic activity and detection sensitivity of profenofos. Under optimum conditions, the GPE/TiO2@NiO-CuO demonstrated an impressively low detection limit of 0.00132 µg/L, coupled with a favorable detection range spanning from 1.0 μg/L to 10 μg/L with correlation coefficient R2 = 0.992. Moreover, the electrode demonstrates remarkably very good stability, and repeatability with %RSD is only 0.94% over 11 repeated measurements. These results signify that GPE/TiO2@NiO-CuO for detecting profenofos, demonstrates exceptional excellent linearity, repeatability, and promising sensitivity for pesticide detection.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">GPE/TiO2</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">NiO-CuO nanocomposite</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Electrochemical detection</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Cyclic voltammetry</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">profenofos insecticide</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.abechem.com/article_716161_95a561158f1a63c056ec51f17f9c0992.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Analytical and Bioanalytical Electrochemistry is an international scientific journal published online by the Center of Excellence in Electrochemistry at the University of Tehran, Tehran, Iran. The journal was published quarterly from 2009 to 2011, bimonthly from 2011 to 2018, and has been published in at least eight issues per year since 2018.</PublisherName>
				<JournalTitle>Analytical and Bioanalytical Electrochemistry</JournalTitle>
				<Issn>-</Issn>
				<Volume>16</Volume>
				<Issue>9</Issue>
				<PubDate PubStatus="epublish">
					<Year>2024</Year>
					<Month>09</Month>
					<Day>30</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Corrosion Protection Performance of a Derivative of Quinoline [5-((3-Propyl-1H-Pyrrol-1-Yl) Methyl) Quinolin-8-Ol] PPMQ On Carbon Steel in Hydrochloric Acidic Solution 1 M</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>862</FirstPage>
			<LastPage>880</LastPage>
			<ELocationID EIdType="pii">716172</ELocationID>
			
<ELocationID EIdType="doi">10.22034/abec.2024.716172</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Chadine</FirstName>
					<LastName>Belmejdoub</LastName>

						<AffiliationInfo>
						<Affiliation>EMDD_CERNE2D, Mohamed V University of Rabat, EST Salé, Morocco</Affiliation>
						</AffiliationInfo>

						<AffiliationInfo>
						<Affiliation>Laboratory of Engineering and Applied Technologies, School of Technology, Beni Mellal, Morocco</Affiliation>
						</AffiliationInfo>

</Author>
<Author>
					<FirstName>Benbouya</FirstName>
					<LastName>Khalid</LastName>
<Affiliation>EMDD_CERNE2D, Mohamed V University of Rabat, EST Salé, Morocco</Affiliation>

</Author>
<Author>
					<FirstName>Issam</FirstName>
					<LastName>Forsal</LastName>
<Affiliation>Laboratory of Engineering and Applied Technologies, School of Technology, Beni Mellal, Morocco</Affiliation>
<Identifier Source="ORCID">0000-0003-2769-8499</Identifier>

</Author>
<Author>
					<FirstName>Sara</FirstName>
					<LastName>Lahmady</LastName>
<Affiliation>Laboratory of Engineering and Applied Technologies, School of Technology, Beni Mellal, Morocco</Affiliation>
<Identifier Source="ORCID">0000-0003-2769-8499</Identifier>

</Author>
<Author>
					<FirstName>Mohamed</FirstName>
					<LastName>Rbaa</LastName>
<Affiliation>Laboratory of Organic Chemistry, Catalysis and Environment, Faculty of Sciences, Ibn Tofail University, PO Box 133, 14000, Kenitra, Morocco</Affiliation>

</Author>
<Author>
					<FirstName>Rachid</FirstName>
					<LastName>Touir</LastName>
<Affiliation>Regional Center for Education and Training Professions (CRMEF), Kenitra, Morocco</Affiliation>
<Identifier Source="ORCID">0000-0003-2796-2157</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2024</Year>
					<Month>02</Month>
					<Day>25</Day>
				</PubDate>
			</History>
		    <Abstract>Organic inhibitors play a crucial role in the corrosion inhibition process. In this work, the performance of the derivative of quinoline PPMQ against corrosion of carbon steel in the acidic medium HCl 1 M was assessed using electrochemical methods. The findings of the experiments showed that the inhibitor had a strong inhibitory impact on the metal tested in the hydrochloric acid solution. The outcomes of the study displayed that the inhibition efficiency of the tested inhibitor enhanced with its concentrations and remained almost stable during immersion time while decreasing slightly with rising temperature. Electrochemical measurements of this study showed that the corrosion was greatly decreased by the organic inhibitor through a charge transfer mechanism with a high inhibition efficiency of 95.58% at an optimal concentration of 10-2 M at 293 K. While potentiodynamic polarization data reported that the inhibitor was a mixed-type inhibitor. PPMQ was inclined towards the Langmuir adsorption isotherm by spontaneous chemical-physical adsorption on the surface of carbon steel. Additionally, thermodynamic and activation data revealed that this action occurs through an endothermic process. Scanning electron microscopy findings showed that the inhibitor’s molecules form a protective layer, which confirms the electrochemical results.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Organic inhibitor</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">acidic medium</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Electrochemical measurements</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">SEM analysis</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Thermodynamic parameters</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.abechem.com/article_716172_f13ca59e574a14d28a6d715662875065.pdf</ArchiveCopySource>
</Article>

<Article>
<Journal>
				<PublisherName>Analytical and Bioanalytical Electrochemistry is an international scientific journal published online by the Center of Excellence in Electrochemistry at the University of Tehran, Tehran, Iran. The journal was published quarterly from 2009 to 2011, bimonthly from 2011 to 2018, and has been published in at least eight issues per year since 2018.</PublisherName>
				<JournalTitle>Analytical and Bioanalytical Electrochemistry</JournalTitle>
				<Issn>-</Issn>
				<Volume>16</Volume>
				<Issue>9</Issue>
				<PubDate PubStatus="epublish">
					<Year>2024</Year>
					<Month>09</Month>
					<Day>30</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Investigating The Effect of Substitution on The Efficiency of Some Hydrazone Ligands in Using Them as Ionophores in The Construction of Membrane Sensors for Cr3+ Ions</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>881</FirstPage>
			<LastPage>891</LastPage>
			<ELocationID EIdType="pii">716175</ELocationID>
			
<ELocationID EIdType="doi">10.22034/abec.2024.716175</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Hediye</FirstName>
					<LastName>Moblsaz Fard</LastName>
<Affiliation>Department of Chemistry, Faculty of Science, Imam Khomeini International University, Qazvin, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Farhang</FirstName>
					<LastName>Mizani</LastName>
<Affiliation>Department of Chemistry, Faculty of Science, Imam Khomeini International University, Qazvin, Iran</Affiliation>
<Identifier Source="ORCID">0000-0002-8027-1278</Identifier>

</Author>
<Author>
					<FirstName>Neda</FirstName>
					<LastName>Heydari</LastName>
<Affiliation>Department of Chemistry, Faculty of Science, Imam Khomeini International University, Qazvin, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2024</Year>
					<Month>08</Month>
					<Day>02</Day>
				</PubDate>
			</History>
		    <Abstract>Chromium is a metallic element that is used in various industries. Because when chromium is placed in the environment, it is possible to be absorbed by humans and other environmental receptors, which is why the control of this element is very important. Ion-selective electrodes are commonly used today to measure a large number of cations and anions, which do not have some of the problems of the other analytical methods. In this study, to design and build a new chromium ion-selective potentiometric sensor, two ligands (E)-4-amino-N&#039;-(5-bromo-2-hydroxybenzylidene) benzohydrazide (LP5) and (E)-4-amino-N&#039;-(2-hydroxy-3-methoxybenzylidene) benzohydrazide (LP7) was used as ionophores. Then, two ligands used as ionophores were compared in terms of performance and efficiency, and finally the best ionophore was selected for further experiments. The potentiometric responses of electrodes for both ligands were without any changes in the pH range of 2.5 to 10. The electrode with LP5 ligand showed a detection limit of 9.8×10-8 and the LP7 ligand showed a detection limit of 9.5×10-8. As a result, the LP7 ligand indicates a favorable selectivity toward the Cr3+ ion.  The optimal composition of the membrane that led to the desired results was 8% ionophilic, 4% additive, 64% plasticizer, and 24% PVC powder.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Ion selective electrodes</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">PVC-membrane</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Chromium (III) ions</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Hydrazone ligands</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Potentiometric sensor</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.abechem.com/article_716175_d9e960c08c6cd0e34b84ec083203fe21.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
